ENGINE CAPACITOR WORKING 10uF/450V WITH CONNECTORS

The motor start/run capacitor is designed to work with asynchronous electric motors powered by alternating current. In life Everyday we encounter them in:

  • lawn mowers
  • fans
  • central heating circulation pumps
  • Entrance gate actuators
  • and others

TECHNICAL SPECIFICATION

  • Manufacturer SR Passives
  • Capacitor type: polypropylene
  • Application of capacitors for motors, work
  • Capacitance 10µF
  • Operating voltage 450V
  • Body dimensions: 35 x 60mm
  • Operating temperature -25...70°C
  • Tolerance ±5%
  • Climate category 25/70/21
  • Lifespan 3000h
  • Leads CONNECTORS 6.3mm

Capacity selection:

You should always be guided by the documentation and the status found in device. The important information is that you can always increase the capacity ( max by 20%) compared to the damaged one. Too much capacity causes a decrease engine speed and power (actually a drop in torque rotational). Too small capacity means that the engine may have problems with start-up.

Symptoms of capacitor damage:

  • optical inspection - external melting in the form of gray "lava" ++
  • auditory inspection - the engine does not work and roars ++
  • electrical measurement with a meter

++ the methods described above usually determine the damage capacitor, but this may not be the only fault in the system drive.