CAPACITOR MOTOR 40uF/450V WITH MIFLEX CONNECTORS Polish product

LONG LIFETIME 10000 hours

Capacitor starting/running motor is designed to work with asynchronous electric motors powered by alternating current.

Are used:

  • lawn mowers
  • fans
  • central heating circulation pumps
  • Entrance gate actuators
  • and others

SPECIFICATION TECHNICAL

  • Manufacturer MIFLEX
  • Capacitor type: polypropylene
  • Application of capacitors for motors, work
  • Capacitance 40µF
  • Operating voltage 450V
  • Body dimensions Ø45 x 119mm
  • Operating temperature -25...70
  • Tolerance ±10%
  • Climate category 25/701
  • Lifespan 10000h
  • Leads CONNECTORS 6.3mm
  • M8 mounting screw
  • Gross weight: 0.1 kg

Selection capacity:

It is necessary always refer to the documentation, the condition found in the device. Important the information is that you can always increase the capacity (max. 20%) in in relation to the damaged one. Too much capacity causes a drop in speed rotational speed and engine power. Too small a capacity causes the engine to have problem with starting.

Symptom capacitor damage:

  • optical inspection - melting on the outside in the form of gray "lava" ++
  • auditory inspection - engine does not work and roars ++
  • electrical measurement with a meter

++ the methods described above usually determine capacitor damage, but it may not be the only fault in the drive system